Table 4. SPCN Error Codes (continued)
| | |
|
|
|
|
|
| | |
|
|
|
|
|
Error Code Description
1011 2611 Regulator fault
1011 2612 SPCN problem
1011 2613 Power configuration fault
1011 3100 I2C controller fault
1011 3101 I2C bus 1 fault
1011 3102 I2C bus 2 fault
1011 3104 I2C bus 4 fault
1011 3105 I2C bus 5 fault
1011 3106 I2C bus 6 fault
1011 3113 RIO bus adapter fault
1011 3114 PCI backplane fault
1011 3115 Operator panel fault
Action/
Possible Failing FRU
1. Verify that the VSCOMM cable
is functioning and properly
installed.
2. Replace the primary I/O drawer
backplane
Location: U0.1-P1.
1. Verify that the VSCOMM cable
is functioning and properly
installed.
2. Replace the primary I/O drawer
backplane
Location: U0.1-P1.
220 V ac power required
Primary I/O backplane
Location: U0.1-P1
1. Primary drawer op panel
Location: U0.1-L1
2. Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
1. Primary I/O fan controller card
Location: U0.1-X2
2. Primary I/O backplane
Location: U0.1-P1
3. Primary I/O drawer power
distribution board
Location: U0.1-X1
1. CEC drawer fan controller card
Location: U1.1-X2
2. Primary I/O backplane
Location: U0.1-P1
Primary I/O drawer RIO bus
adapter
Location: U0.1-P1.1
Primary I/O PCI backplane
Location: U0.1-P1
Operator panel
Location: U0.1-L1