IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 307

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
450C 300D Memory system and IPL detected
512MB (stacked) DIMM fault
450C 300E Memory system and IPL detected
512MB (unstacked) DIMM fault
450C 301F Memory system and IPL detected
128MB DIMM fault
450C 303A Memory system and IPL detected
1GB DIMM fault
450C 51AA Memory system and IPL detected
645W AC power supply fault
450C 51AB Memory system and IPL detected
645W DC power supply fault
450C 51AC Memory system and IPL detected
595W AC power supply fault
450C 51AD Memory system and IPL detected
595W DC power supply fault
450D 244C Memory system and attention handler
detected 1W processor fault
450D 244D Memory system and attention handler
detected 2W processor fault
450D 244E Memory system and attention handler
detected 4W processor fault
450D 244F Memory system and attention handler
detected 1W processor fault
Action/
Possible Failing FRU
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
All memory DIMMs
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
645W AC power supply
Locations:
U1.1-V1
U1.1-V2
645W DC power supply
Locations:
U1.1-V1
U1.1-V2
595W AC power supply
Locations:
U0.1-V1
U0.1-V2
595W DC power supply
Locations:
U0.1-V1
U0.1-V2
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Chapter 5. Error Code to FRU Index
289

Advertisement

Table of Contents
loading