IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 229

Service guide
Table of Contents

Advertisement

Table 5. Firmware Error Codes. (continued)
Error Code Description
2803 0001 RTC not updating - RTC initialization
required
2803 0002 Bad time/date values
2803 0003 RTC not updating - not correctable
2803 0004 RTC operating mode parameters (eg.
data mode) changed
2803 0005 RTC battery error
2900 0002 Keyboard/mouse controller failed
self-test
29A0 0003 Keyboard not present/detected
29A0 0004 Keyboard stuck key detected
29B0 0004 Mouse not present/detected
Action/
Possible Failing FRU
Errors reported against the real-time
clock can be caused by low battery
voltage and (more rarely) power
outages that occur during normal
system usage. These errors are
warnings that the real-time clock data
content needs to be re-established
and do not require any FRU
replacement unless the error is
persistent. When one of these errors
occurs, the time and date information
has been lost.
To set/restore the time and date, use
the operating system facility.
If the error is persistent:
1. Replace the battery.
2. Replace primary I/O backplane
Location: U0.1-P1
1. Set time and date.
2. Refer to Action under error code
28030001.
Replace primary I/O backplane
Location: U0.1-P1
1. Set time and date.
2. Refer to Action under error code
28030001.
1. Replace the battery.
Note: Password, time, and date
need to be set.
2. Refer to Action under error code
28030001.
Replace primary I/O backplane
Location: U0.1-P1
1. Keyboard
2. Keyboard cable
3. Replace primary I/O backplane
Location: U0.1-P1
1. Keyboard
2. Replace primary I/O backplane
Location: U0.1-P1
1. Mouse
2. Replace primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index
211

Advertisement

Table of Contents
loading

Table of Contents