IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 199

Service guide
Table of Contents

Advertisement

Table 4. SPCN Error Codes (continued)
Error Code Description
1011 8431 Frame ID error
1011 8441 Internal SPCN error in a drawer
10118450 I/O type set incorrectly
1011 8A00 A different I/O drawer is connected to the
CEC
1011 9014 Invalid address mode
1011 9038 Node fault
1011 9039 Node fault
1011 9042 EPROM failure
1011 9043 Download failure
1011 9046 QDS packet sequence error
1011 9047 QDS block sequence error
1011 9080 Undefined status code received
1011 90F0 CEC backplane not present in
configuration table
1011 9101 SPCN failed to respond to service
processor in time
1011 9102 Permanent address assignment failed
Action/
Possible Failing FRU
1. Check cabling
2. Set the I/O type to 85. See
Power Control Network Utilities
Menu on page 389.
3. Primary I/O backplane
Location: U0.1-P1
1. Check the internal SPCN
cables in the CEC drawer
Location: U1.1
2. Check the internal SPCN
cables in the I/O drawer
Location: U0.x
Set the I/O type to 85. See Power
Control Network Utilities Menu on
page 389.
Informational only
Update system firmware
Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
1. Check for system firmware
update.
2. Call service support.
1. Check for system firmware
update.
2. Call service support.
1. Check for system firmware
update.
2. Call service support.
Primary I/O backplane
Location: U0.1-P1
Check cabling
Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index
181