Table 6. Service Processor Error Codes. (continued)
Error Code Description
406D 00B7 Attention handler detected insufficient
hardware resources to continue IPL
406D 0100 Attention handler detected memory
riser card fault
406D 0101 Attention handler detected memory
DIMM fault
406D 0102 Attention handler detected memory
DIMM fault
406D 0103 Attention handler detected memory
DIMM fault
406D 0104 Attention handler detected memory
DIMM fault
406D 010D Attention handler detected memory
DIMM fault
406D 0111 Attention handler detected memory
DIMM fault
406D 0112 Attention handler detected memory
DIMM fault
406D 0113 Attention handler detected memory
DIMM fault
406D 0114 Attention handler detected memory
DIMM fault
406D 011D Attention handler detected memory
DIMM fault
406D 0121 Attention handler detected memory
DIMM fault
406D 0122 Attention handler detected memory
DIMM fault
406D 0123 Attention handler detected memory
DIMM fault
406D 0124 Attention handler detected memory
DIMM fault
406D 012D Attention handler detected memory
DIMM fault
406D 0131 Attention handler detected memory
DIMM fault
Action/
Possible Failing FRU
This error code appears after the
initial testing by the service processor
firmware on the CEC was completed
correctly, but a problem occurred
when the firmware tried to
communicate outside the CEC.
Suspect a problem with the RIO
interface, either cables or adapters.
Memory riser card
Location: U1.1-P1-M2
Memory DIMM
Location: U1.1-P1-M2.15
Memory DIMM
Location: U1.1-P1-M2.1
Memory DIMM
Location: U1.1-P1-M2.16
Memory DIMM
Location: U1.1-P1-M2.2
Memory DIMM
Location: U1.1-P1-M2.1 x4
Memory DIMM
Location: U1.1-P1-M2.13
Memory DIMM
Location: U1.1-P1-M2.3
Memory DIMM
Location: U1.1-P1-M2.14
Memory DIMM
Location: U1.1-P1-M2.4
Memory DIMM
Location: U1.1-P1-M2.3 x4
Memory DIMM
Location: U1.1-P1-M2.11
Memory DIMM
Location: U1.1-P1-M2.5
Memory DIMM
Location: U1.1-P1-M2.12
Memory DIMM
Location: U1.1-P1-M2.6
Memory DIMM
Location: U1.1-P1-M2.5 x4
Memory DIMM
Location: U1.1-P1-M2.9
Chapter 5. Error Code to FRU Index