Step 1020-4
1. Turn off, then turn on the system unit.
2. When the keyboard indicator (the word keyboard) is displayed, press the 1 key on
the system console.
3. When the System Management Services menus appear, check the error log for any
errors.
a. Choose Error Log
b. If an error is logged, check the time stamp.
c. If the error was logged during the current boot attempt, record it.
d. Look up the error in the Chapter 5, "Error Code to FRU Index" on page 163 and
e. If no recent error is logged in the error log, go to "MAP 1540: Minimum
88
Service Guide
do the listed action.
Configuration" on page 113.