IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 329

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
460A 288D I/O system and self test detected
memory riser fault
460A 2A00 I/O system and self test detected 6W
processor fault
460A 300A I/O system and self test detected
32MB DIMM fault
460A 300B I/O system and self test detected
128MB DIMM fault
460A 300C I/O system and self test detected
256MB DIMM fault
460A 300D I/O system and self test detected
512MB (stacked) DIMM fault
460A 300E I/O system and self test detected
512MB (unstacked) DIMM fault
460A 301F I/O system and self test detected
512MB DIMM fault
Action/
Possible Failing FRU
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
Processor card
Location: U1.1-P1-C1
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Chapter 5. Error Code to FRU Index
311

Advertisement

Table of Contents
loading

Table of Contents