Table 6. Service Processor Error Codes. (continued)
Error Code Description
460D 300C I/O system and attention handler
detected 256MB DIMM fault
460D 300D I/O system and attention handler
detected 512MB (stacked) DIMM
fault
460D 300E I/O system and attention handler
detected 512MB (unstacked) DIMM
fault
460D 301F I/O system and attention handler
detected 128MB DIMM fault
460D 303A I/O system and attention handler
detected 1GB DIMM fault
460D 51AA I/O system and attention handler
detected 645W AC power supply fault
460D 51AB I/O system and attention handler
detected 645W DC power supply
fault
460D 51AC I/O system and attention handler
detected 595W AC power supply fault
460D 51AD I/O system and attention handler
detected 595W DC power supply
fault
460E 244C I/O system and scan control routines
detected 1W processor fault
460E 244D I/O system and scan control routines
detected 2W processor fault
Action/
Possible Failing FRU
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
645W AC power supply
Locations:
U1.1-V1
U1.1-V2
645W DC power supply
Locations:
U1.1-V1
U1.1-V2
595W AC power supply
Locations:
U0.1-V1
U0.1-V2
595W DC power supply
Locations:
U0.1-V1
U0.1-V2
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Chapter 5. Error Code to FRU Index
319