Firmware Error Codes - IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual

Service guide
Table of Contents

Advertisement

Firmware Error Codes

Attention:
corrected, go to "MAP 1540: Minimum Configuration" on page 113 unless otherwise
indicated in the tables.
If you replace FRUs and the problem is corrected, go to "MAP 410: Repair Checkout"
in the RS/6000 and Eserver pSeries Diagnostics Information for Multiple Bus Systems .
Table 5. Firmware Error Codes.
190
Service Guide
If you replace FRUs or perform an action and the problem is still not
Error Code Description
2011 00xy I/O drawer power supply failure
2022 0000 The I/O system is running slowly.
Action/
Possible Failing FRU
1. Replace power supply "y" in I/O
drawer "x".
If y=_, then the power supply is:
y = power supply
3 = Both power supplies
(I/O drawer)
2 = Reserved
1 = Reserved
See "AIX and Physical Location
Code Tables" in Chapter 1 for
location codes.
2. Check AC power source to I/O
drawer "x".
See "AIX and Physical Location
Code Tables" in Chapter 1 for
location codes.
1. Check cabling
2. Call for support