IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 299

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
4509 300E Memory system and memory test
detected 512MB (unstacked) DIMM
fault
4509 301F Memory system and memory test
detected 128MB DIMM fault
4509 303A Memory system and memory test
detected 1GB DIMM fault
4509 51AA Memory system and memory test
detected 645W AC power supply fault
4509 51AB Memory system and memory test
detected 645W DC power supply
fault
4509 51AC Memory system and memory test
detected 595W AC power supply fault
4509 51AD Memory system and memory test
detected 595W DC power supply
fault
450A 244C Memory system and self test
detected 1W processor fault
450A 244D Memory system and self test
detected 2W processor fault
450A 244E Memory system and self test
detected 4W processor fault
450A 244F Memory system and self test
detected 1W MHz processor fault
450A 248B Memory system and self test
detected primary I/O drawer operator
panel
450A 24A1 Memory system and self test
detected 1W processor fault
Action/
Possible Failing FRU
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
645W AC power supply
Locations:
U1.1-V1
U1.1-V2
645W DC power supply
Locations:
U1.1-V1
U1.1-V2
595W AC power supply
Locations:
U0.1-V1
U0.1-V2
595W DC power supply
Locations:
U0.1-V1
U0.1-V2
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Operator panel
Location: U0.1-L1
Processor card
Location: U1.1-P1-C1
Chapter 5. Error Code to FRU Index
281

Advertisement

Table of Contents
loading

Table of Contents