Table 4. SPCN Error Codes (continued)
Error Code Description
1011 311C Primary I/O drawer thermal malfunction
176
Service Guide
1011 3116 Primary I/O drawer fan controller fault
1011 3117 CEC drawer fan controller fault
1011 3118 Backplane fault
1011 311B CEC thermal malfunction
1011 7610 Slow I/O drawer fan 1
1011 7611 Missing I/O drawer fan 1
1011 7620 Slow I/O drawer fan 2
1011 7621 Missing I/O drawer fan 2
1011 7630 Slow I/O drawer fan 3
1011 7631 Missing I/O drawer fan 3
Action/
Possible Failing FRU
1. Primary I/O drawer fan
controller card
Location: U0.1-X2
2. Primary I/O backplane
Location: U0.1-P1
1. CEC drawer fan controller card
Location: U1.1-X2
2. Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
CEC backplane
Location: U1.1-P1
1. Primary I/O Op Panel
Location: U0.1-L1
2. Primary I/O backplane
Location: U0.1-P1
1. Fan 1
Location: U0.1-F1
2. Primary fan controller
Location: U0.1-X2
3. Power distribution card
Location: U0.1-X1
Fan 1
Location: U0.1-F1
1. Fan 2
Location: U0.1-F2
2. Primary fan controller
Location: U0.1-X2
3. Power distribution card
Location: U0.1-X1
Fan 2
Location: U0.1-F2
1. Fan 3
Location: U0.1-F3
2. Primary fan controller
Location: U0.1-X2
3. Power distribution card
Location: U0.1-X1
Fan 3
Location: U0.1-F3