Table 6. Service Processor Error Codes. (continued)
Error Code Description
4067 0233 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0234 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 023D 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 02FF 6xx bus processor runtime
diagnostics detected memory on riser
card fault
4067 0300 6xx bus processor runtime
diagnostics detected processor card
fault
4067 0301 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0302 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 030D 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0311 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0312 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 031D 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0321 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0322 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 032D 6xx bus processor runtime
diagnostics detected memory DIMM
fault
Action/
Possible Failing FRU
Memory DIMM
Location: U1.1-P1-M1.10
Memory DIMM
Location: U1.1-P1-M1.8
Memory DIMM
Location: U1.1-P1-M1.7 x4
Memory failure on riser card 1 that
cannot be automatically isolated. Go
to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
Processor card
Location: U1.1-P1-C1
Memory DIMM
Location: U1.1-P1-C1-M8
Memory DIMM
Location: U1.1-P1-C1-M1
Memory DIMM
Location: U1.1-P1-C1-M1 x2
Memory DIMM
Location: U1.1-P1-C1-M7
Memory DIMM
Location: U1.1-P1-C1-M2
Memory DIMM
Location: U1.1-P1-C1-M2 x2
Memory DIMM
Location: U1.1-P1-C1-M6
Memory DIMM
Location: U1.1-P1-C1-M3
Memory DIMM
Location: U1.1-P1-C1-M3 x2
Chapter 5. Error Code to FRU Index
223