IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 222

Service guide
Table of Contents

Advertisement

Table 5. Firmware Error Codes. (continued)
204
Service Guide
Error Code Description
21F2 0003 SCSI read/write optical - send
diagnostic failed- sense data
available
21F2 0004 SCSI read/write optical - send
diagnostic failed- DevOfl cmd
2200 0001 PCI Ethernet BNC/RJ-45 or PCI
Ethernet AUI/RJ-45 Adapter
internal wrap test failure
2200 1001 10/100 Mbps Ethernet PCI Adapter
internal wrap test failure
2201 0001 PCI Auto LANstreamer token ring
adapter
Adapter failed to complete hardware
initialization.
2201 1001 PCI token ring adapter
Adapter failed to complete hardware
initialization.
25A0 0001 Cache L2 controller failure
25A1 0001 Cache L2 SRAM failure
Action/
Possible Failing FRU
Before replacing any system
components, refer to the notes in
error code 21A0 0001.
Replace the SCSI device.
Before replacing any system
components, refer to the notes in
error code 21A0 0001.
Replace the SCSI device.
Replace the adapter.
See "Checkpoint and Error Code
Index" on page 165 for location code
information related to this error. Also
see "Replacing the Network Adapter"
on page 163.
Replace the adapter.
See "Checkpoint and Error Code
Index" on page 165 for location code
information related to this error. Also
see "Replacing the Network Adapter"
on page 163.
Replace the adapter.
See "Checkpoint and Error Code
Index" on page 165 for location code
information related to this error. Also
see "Replacing the Network Adapter"
on page 163.
Replace the adapter.
See "Checkpoint and Error Code
Index" on page 165 for location code
information related to this error. Also
see "Replacing the Network Adapter"
on page 163.
1. Replace the processor card.
Location: U1.1-P1-C1
2. Replace the CEC backplane
assembly.
Location: U1.1-P1.
1. Replace the processor card.
Location: U1.1-P1-C1

Advertisement

Table of Contents
loading