Table 6. Service Processor Error Codes. (continued)
220
Service Guide
Error Code Description
4067 00B7 6xx bus processor runtime
diagnostics detected insufficient
hardware resources to continue IPL
4067 0100 6xx bus processor runtime
diagnostics detected memory riser
card fault
4067 0101 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0102 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0103 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0104 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 010D 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0111 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0112 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0113 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0114 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 011D 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0121 6xx bus processor runtime
diagnostics detected memory DIMM
fault
Action/
Possible Failing FRU
This error code appears after the
initial testing by the service processor
firmware on the CEC was completed
correctly, but a problem occurred
when the firmware tried to
communicate outside the CEC.
Suspect a problem with the RIO
interface, either cables or adapters.
Memory riser card
Location: U1.1-P1-M2
Memory DIMM
Location: U1.1-P1-M2.15
Memory DIMM
Location: U1.1-P1-M2.1
Memory DIMM
Location: U1.1-P1-M2.16
Memory DIMM
Location: U1.1-P1-M2.2
Memory DIMM
Location: U1.1-P1-M2.1 x4
Memory DIMM
Location: U1.1-P1-M2.13
Memory DIMM
Location: U1.1-P1-M2.3
Memory DIMM
Location: U1.1-P1-M2.14
Memory DIMM
Location: U1.1-P1-M2.4
Memory DIMM
Location: U1.1-P1-M2.3 x4
Memory DIMM
Location: U1.1-P1-M2.11

Advertisement