Table 6. Service Processor Error Codes. (continued)
Error Code Description
460E 288D I/O system and scan control routines
detected memory riser fault
460E 2A00 I/O system and scan control routines
detected 6W processor fault
460E 300A I/O system and scan control routines
detected 32MB DIMM fault
460E 300B I/O system and scan control routines
detected 128MB DIMM fault
460E 300C I/O system and scan control routines
detected 256MB DIMM fault
460E 300D I/O system and scan control routines
detected 512MB (stacked) DIMM
fault
460E 300E I/O system and scan control routines
detected 512MB (unstacked) DIMM
fault
460E 301F I/O system and scan control routines
detected 128MB DIMM fault
Action/
Possible Failing FRU
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
Processor card
Location: U1.1-P1-C1
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Chapter 5. Error Code to FRU Index
321

Advertisement

Table of Contents
loading

Table of Contents