IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 301

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
450A 288D Memory system and self test
detected memory riser fault
450A 2A00 Memory system and self test
detected 6W processor fault
450A 300A Memory system and self test
detected 32MB DIMM fault
450A 300B Memory system and self test
detected 128MB DIMM fault
450A 300C Memory system and self test
detected 256MB DIMM fault
450A 300D Memory system and self test
detected 512MB (stacked) DIMM
fault
450A 300E Memory system and self test
detected 512MB (unstacked) DIMM
fault
450A 301F Memory system and self test
detected 128MB DIMM fault
Action/
Possible Failing FRU
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
Processor card
Location: U1.1-P1-C1
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
All memory DIMMs
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Chapter 5. Error Code to FRU Index
283

Advertisement

Table of Contents
loading

Table of Contents