Table 6. Service Processor Error Codes. (continued)
Error Code Description
4069 3201 Memory test detected primary I/O
backplane fault
4069 3280 Memory test detected primary RIO
adapter fault
4069 3281 Memory test detected primary RIO
port 0 fault
4069 3282 Memory test detected primary RIO
port 1 fault
4069 3283 Memory test detected primary RIO
ports fault
4069 3284 Memory Test detected PCI controller
PHB0 fault
4069 3285 Memory Test detected PCI controller
PHB1 fault
4069 3286 Memory Test detected PCI controller
PHB2 fault
406A 0001 Self test detected CEC backplane
fault
406A 0003 Self test detected processor fault
406A 0009 Self test detected memory fault
406A 00A0 Self test detected service processor
firmware fault
406A 00A1 Self test detected system firmware
fault
Action/
Possible Failing FRU
Primary I/O backplane
Location: U0.1-P1
Primary RIO adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q1
2. Primary RIO adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q2
2. Primary RIO adapter
Location: U0.1-P1.1
Primary RIO adapter
Location: U0.1-P1.1
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
CEC backplane
Location: U1.1-P1
All processors
Location: U1.1-P1-C1
All memory
Locations:
U1.1-P1-C1
U1.1-P1-M1
U1.1-P1-M2.
Go to "MAP 1540: Minimum
Configuration" on page 113 and run
CEC drawer minimum configuration
to isolate the failing memory
component.
Update system firmware
1. Check for AIX updates
2. Check for system firmware
update
Chapter 5. Error Code to FRU Index