IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 259

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
406A 02FF Self test detected memory on riser
card fault
406A 0300 Self test detected processor card
fault
406A 0301 Self test detected memory DIMM
fault
406A 0302 Self test detected memory DIMM
fault
406A 030D Self test detected memory DIMM
fault
406A 0311 Self test detected memory DIMM
fault
406A 0312 Self test detected memory DIMM
fault
406A 031D Self test detected memory DIMM
fault
406A 0321 Self test detected memory DIMM
fault
406A 0322 Self test detected memory DIMM
fault
406A 032D Self test detected memory DIMM
fault
406A 0331 Self test detected memory DIMM
fault
406A 0332 Self test detected memory DIMM
fault
406A 033D Self test detected memory DIMM
fault
406A 03FF Self test detected memory on
processor card fault
406A 3101 Self test detected RIO port 0 fault
Action/
Possible Failing FRU
Memory failure on riser card 1 that
cannot be automatically isolated. Go
to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
Processor card
Location: U1.1-P1-C1
Memory DIMM
Location: U1.1-P1-C1-M8
Memory DIMM
Location: U1.1-P1-C1-M1
Memory DIMM
Location: U1.1-P1-C1-M1 x2
Memory DIMM
Location: U1.1-P1-C1-M7
Memory DIMM
Location: U1.1-P1-C1-M2
Memory DIMM
Location: U1.1-P1-C1-M2 x2
Memory DIMM
Location: U1.1-P1-C1-M6
Memory DIMM
Location: U1.1-P1-C1-M3
Memory DIMM
Location: U1.1-P1-C1-M3 x2
Memory DIMM
Location: U1.1-P1-C1-M5
Memory DIMM
Location: U1.1-P1-C1-M4
Memory DIMM
Location: U1.1-P1-C1-M4 x2
Memory failure on processor card
that cannot be automatically isolated.
Go to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
1. Processor card
Location: U1.1-P1-C1
2. CEC drawer backplane
Location: U1.1-P1
Chapter 5. Error Code to FRU Index
241

Advertisement

Table of Contents
loading

Table of Contents