Table 6. Service Processor Error Codes. (continued)
Error Code Description
4067 00A0 6xx bus processor runtime
diagnostics detected service
processor firmware fault
4067 00A1 6xx bus processor runtime
diagnostics detected system firmware
fault
4067 00A2 6xx bus processor runtime
diagnostics detected service
processor firmware (processor
runtime diagnostics) fault
4067 00A3 6xx bus processor runtime
diagnostics detected memory
plugging fault
4067 00A4 6xx bus processor runtime
diagnostics detected application
caused fault
4067 00A5 6xx bus processor runtime
diagnostics detected invalid system
configuration
4067 00A6 6xx bus processor runtime
diagnostics detected no usable
memory
4067 00A7 6xx bus processor runtime
diagnostics detected hardware
problem
4067 00B0 6xx bus processor runtime
diagnostics detected bus controller
lock-unlock failure
4067 00B1 6xx bus processor runtime
diagnostics detected bus controller
failure
Action/
Possible Failing FRU
Update system firmware
1. Check for AIX updates
2. Check for system firmware
update
Check for system firmware update
All pluggable memory.
Go to "MAP 1540: Minimum
Configuration" on page 113and run
CEC drawer minimum configuration
to isolate the failing memory
component.
Application software
Verify system components are
supported and properly installed
1. Ensure that memory DIMMS and
cards are properly installed
2. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
3. Go to "MAP 1540: Minimum
Configuration" on page 113.
Go to "MAP 1540: Minimum
Configuration" on page 113.
RIO adapter
Location: U0.1-P1.1
RIO adapter
Location: U0.1-P1.1
Chapter 5. Error Code to FRU Index
219