Table 6. Service Processor Error Codes. (continued)
Error Code Description
4B2E 25BB Processor system and scan control
routines detected 1W processor card
fault
4B2E 25BD Processor system and scan control
routines detected 2W processor card
fault
4B2E 25BE Processor system and scan control
routines detected 4W processor card
fault
4B2E 25BF Processor system and scan control
routines detected 6W processor card
fault
4B2E 25CB 1W processor card fault
4B2E 25EA 4W processor card fault
4B2E 25EB 2W processor card fault
4B2E 25F2 6W processor card fault
4B2E 263D Processor system and scan control
routines detected dummy riser card
fault
4B2E 2687 Processor system and scan control
routines detected RIO adapter fault
4B2E 271A Processor system and scan control
routines detected primary I/O
backplane fault
4B2E 271D Processor system and scan control
routines detected secondary I/O
backplane fault
4B2E 283A Processor system and scan control
routines detected CEC backplane
fault
4B2E 285D Processor system and scan control
routines detected fan controller card
fault
Action/
Possible Failing FRU
1W Processor card
Location: U1.1-P1-C1
2W Processor card
Location: U1.1-P1-C1
4W Processor card
Location: U1.1-P1-C1
6W Processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Dummy riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
RIO adapter
Location: U0.1-P1.1
Primary I/O backplane
Location: U0.1-P1
Secondary I/O backplane
Location: U0.2-P1
1. Processor card
Location: U1.1-P1-C1
2. CEC backplane
Location: U1.1-P1
Fan controller card
Locations:
U0.1-X2
U1.1-X2
Chapter 5. Error Code to FRU Index
349