System Power Control Menu

This menu is used to set power control options. Other menus that control boot options are available here:
SYSTEM POWER CONTROL MENU
1. Enable/Disable Unattended Start Mode:
Currently Enabled
2. Ring-Indicate Power-On Menu
3. Reboot/Restart Policy Setup Menu
4. Power-On System
5. Power-Off System
6. Enable/Disable Fast System Boot
Currently Enabled
7. Boot Mode Menu
98. Return to Previous Menu
99. Exit from Menus
1>
v Enable/Disable Unattended Start Mode
Use this option to instruct the service processor to restore the power state of the server after a
temporary power failure. Unattended start mode can also be set through the System Management
Services (SMS) menus. It is intended to be used on servers that require automatic power-on after a
power failure. For more information, see "System Power-On Methods" on page 386.
v Ring-Indicate Power-On Menu
RING-INDICATE POWER-ON MENU
1. Ring-indicate power-on :
Currently Enabled
2. Number of rings:
Currently 3
30. Refresh Modem Settings
98. Return to Previous Menu
Ring-indicate is enabled by default on both serial port 1 (S1) and serial port 2 (S2). When ring-indicate
power-on is enabled, call-in is disabled.
If ring-indicate power-on is enabled and call-in is already enabled, you will be asked to confirm your
choice. Refer to the message displayed on your screen.
368
Service Guide