Table 6. Service Processor Error Codes. (continued)
324
Service Guide
Error Code Description
460F 288D I/O system and error code
generation/logging detected memory
riser fault
460F 2A00 I/O system and error code
generation/logging detected 6W
processor fault
460F 300A I/O system and error code
generation/logging detected 32MB
DIMM fault
460F 300B I/O system and error code
generation/logging detected 128MB
DIMM fault
460F 300C I/O system and error code
generation/logging detected 256MB
DIMM fault
460F 300D I/O system and error code
generation/logging detected 512MB
(stacked) DIMM fault
460F 300E I/O system and error code
generation/logging detected 512MB
(unstacked) DIMM fault
460F 301F I/O system and error code
generation/logging detected 128MB
DIMM fault
Action/
Possible Failing FRU
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
Processor card
Location: U1.1-P1-C1
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn