IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 313

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
450E 303A Memory System and scan control
routines detected 1GB DIMM fault
450E 51AA Memory system and scan control
routines detected 645W AC power
supply fault
450E 51AB Memory system and scan control
routines detected 645W DC power
supply fault
450E 51AC Memory system and scan control
routines detected 595W AC power
supply fault
450E 51AD Memory system and scan control
routines detected 595W DC power
supply fault
450F 244C Memory system and error code
generation/logging detected 1W
processor fault
450F 244D Memory system and error code
generation/logging detected 2W
processor fault
450F 244E Memory system and error code
generation/logging detected 4W
processor fault
450F 244F Memory system and error code
generation/logging detected 1W
processor fault
450F 248B Memory system and error code
generation/logging detected primary
I/O drawer operator panel
450F 24A1 Memory system and error code
generation/logging detected 1W
processor fault
450F 24A2 Memory system and error code
generation/logging detected 2W
processor fault
450F 24A3 Memory system and error code
generation/logging detected 4W
processor fault
Action/
Possible Failing FRU
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
645W AC power supply
Locations:
U1.1-V1
U1.1-V2
645W DC power supply
Locations:
U1.1-V1
U1.1-V2
595W AC power supply
Locations:
U0.1-V1
U0.1-V2
595W DC power supply
Locations:
U0.1-V1
U0.1-V2
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Operator panel
Location: U0.1-L1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Chapter 5. Error Code to FRU Index
295

Advertisement

Table of Contents
loading

Table of Contents