IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 233

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
4066 0114 Scan interface basic assurance tests
detected memory DIMM fault
4066 011D Scan interface basic assurance tests
detected memory DIMM fault
4066 0121 Scan interface basic assurance tests
detected memory DIMM fault
4066 0122 Scan interface basic assurance tests
detected memory DIMM fault
4066 0123 Scan interface basic assurance tests
detected memory DIMM fault
4066 0124 Scan interface basic assurance tests
detected memory DIMM fault
4066 012D Scan interface basic assurance tests
detected memory DIMM fault
4066 0131 Scan interface basic assurance tests
detected memory DIMM fault
4066 0132 Scan interface basic assurance tests
detected memory DIMM fault
4066 0133 Scan interface basic assurance tests
detected memory DIMM fault
4066 0134 Scan interface basic assurance tests
detected memory DIMM fault
4066 013D Scan interface basic assurance tests
detected memory DIMM fault
4066 01FF Scan interface basic assurance tests
detected memory on riser card fault
4066 0200 Scan interface basic assurance tests
detected memory riser card fault
4066 0201 Scan interface basic assurance tests
detected memory DIMM fault
4066 0202 Scan interface basic assurance tests
detected memory DIMM fault
4066 0203 Scan interface basic assurance tests
detected memory DIMM fault
4066 0204 Scan interface basic assurance tests
detected memory DIMM fault
4066 020D Scan interface basic assurance tests
detected memory DIMM fault
Action/
Possible Failing FRU
Memory DIMM
Location: U1.1-P1-M2.4
Memory DIMM
Location: U1.1-P1-M2.3 x4
Memory DIMM
Location: U1.1-P1-M2.11
Memory DIMM
Location: U1.1-P1-M2.5
Memory DIMM
Location: U1.1-P1-M2.12
Memory DIMM
Location: U1.1-P1-M2.6
Memory DIMM
Location: U1.1-P1-M2.5 x4
Memory DIMM
Location: U1.1-P1-M2.9
Memory DIMM
Location: U1.1-P1-M2.7
Memory DIMM
Location: U1.1-P1-M2.10
Memory DIMM
Location: U1.1-P1-M2.8
Memory DIMM
Location: U1.1-P1-M2.7 x4
Memory failure on riser card 2 that
cannot be automatically isolated. Go
to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
Memory riser card
Location: U1.1-P1-M1
Memory DIMM
Location: U1.1-P1-M1.15
Memory DIMM
Location: U1.1-P1-M1.1
Memory DIMM
Location: U1.1-P1-M1.16
Memory DIMM
Location: U1.1-P1-M1.2
Memory DIMM
Location: U1.1-P1-M1.1 x4
Chapter 5. Error Code to FRU Index
215

Advertisement

Table of Contents
loading