Table 6. Service Processor Error Codes. (continued)
346
Service Guide
Error Code Description
4B2D 248B Processor system and attention
handler detected primary I/O drawer
operator panel
4B2D 24A1 Processor system and attention
handler detected 1W processor fault
4B2D 24A2 Processor system and attention
handler detected 2W processor fault
4B2D 24A3 Processor system and attention
handler detected 4W processor fault
4B2D 24A4 Processor system and attention
handler detected 6W processor fault
4B2D 25BB Processor system and attention
handler detected 1W processor card
fault
4B2D 25BD Processor system and attention
handler detected 2W processor card
fault
4B2D 25BE Processor system and attention
handler detected 4W processor card
fault
4B2D 25BF Processor system and attention
handler detected 6W processor card
fault
4B2D 25CB 1W processor card fault
4B2D 25EA 4W processor card fault
4B2D 25EB 2W processor card fault
4B2D 25F2 6W processor card fault
4B2D 263D Processor system and attention
handler detected dummy riser card
fault
4B2D 2687 Processor system and attention
handler detected RIO adapter fault
4B2D 271A Processor system and attention
handler detected primary I/O
backplane fault
4B2D 271D Processor system and attention
handler detected secondary I/O
backplane fault
Action/
Possible Failing FRU
Operator panel
Location: U0.1-L1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
1W Processor card
Location: U1.1-P1-C1
2W Processor card
Location: U1.1-P1-C1
4W Processor card
Location: U1.1-P1-C1
6W Processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Dummy riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
RIO adapter
Location: U0.1-P1.1
Primary I/O backplane
Location: U0.1-P1
Secondary I/O backplane
Location: U0.2-P1