Table 6. Service Processor Error Codes. (continued)
Error Code Description
406C 3102 IPL detected RIO port 1 fault
406C 3121 IPL detected RIO cable on port 0
fault
406C 3122 IPL detected RIO cable on port 1
fault
406C 31FF IPL detected RIO port fault
406C 3200 IPL detected primary I/O drawer fault
406C 3201 IPL detected primary I/O backplane
fault
406C 3280 IPL detected primary RIO adapter
fault
406C 3281 IPL detected primary RIO port 0 fault
406C 3282 IPL detected primary RIO port 1 fault
406C 3283 IPL detected primary RIO ports fault
406C 3284 IPL detected PCI controller PHB0
fault
406C 3285 IPL detected PCI controller PHB1
fault
406C 3286 IPL detected PCI controller PHB2
fault
406D 0001 Attention handler detected CEC
backplane fault
406D 0003 Attention handler detected processor
fault
Action/
Possible Failing FRU
1. Processor card
Location: U1.1-P1-C1
2. CEC drawer backplane
Location: U1.1-P1
RIO cable on port 0
Location: U1.1-P1/Q3
RIO cable on port 1
Location: U1.1-P1/Q2
Processor card
Location: U1.1-P1-C1
Go to "MAP 1540: Minimum
Configuration" on page 113.
Primary I/O backplane
Location: U0.1-P1
Primary RIO adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q1
2. Primary RIO adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q2
2. Primary RIO adapter
Location: U0.1-P1.1
Primary RIO adapter
Location: U0.1-P1.1
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
CEC backplane
Location: U1.1-P1
All processors
Location: U1.1-P1-C1