Table 6. Service Processor Error Codes. (continued)
318
Service Guide
Error Code Description
460D 25BE I/O system and attention handler
detected 4W processor card fault
460D 25BF I/O system and attention handler
detected 6W processor card fault
460D 263D I/O system and attention handler
detected dummy riser card fault
460D 2687 I/O system and attention handler
detected RIO adapter fault
460D 271A I/O system and attention handler
detected primary I/O backplane fault
460D 271D I/O system and attention handler
detected secondary I/O backplane
fault
460D 283A I/O system and attention handler
detected CEC backplane fault
460D 285D I/O system and attention handler
detected fan controller card fault
460D 288D I/O system and attention handler
detected memory riser fault
460D 2A00 I/O system and attention handler
detected 6W processor fault
460D 300A I/O system and attention handler
detected 32MB DIMM fault
460D 300B I/O system and attention handler
detected 128MB DIMM fault
Action/
Possible Failing FRU
4W Processor card
Location: U1.1-P1-C1
6W Processor card
Location: U1.1-P1-C1
Dummy riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
RIO adapter
Location: U0.1-P1.1
Primary I/O backplane
Location: U0.1-P1
Secondary I/O backplane
Location: U0.2-P1
1. Processor card
Location: U1.1-P1-C1
2. CEC backplane
Location: U1.1-P1
Fan controller card
Locations:
U0.1-X2
U1.1-X2
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
Processor card
Location: U1.1-P1-C1
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn

Advertisement