Table 6. Service Processor Error Codes. (continued)
232
Service Guide
Error Code Description
4068 3286 Other bus processor runtime
diagnostics detected PCI Controller
PHB2 Fault
4069 0001 Memory test detected CEC
backplane fault
4069 0003 Memory test detected processor fault All processors
4069 0009 Memory test detected memory fault
4069 00A0 Memory test detected service
processor firmware fault
4069 00A1 Memory test detected system
firmware fault
4069 00A2 Memory test detected service
processor firmware (processor
runtime diagnostics) fault
4069 00A3 Memory test detected memory
plugging fault
4069 00A4 Memory test detected application
caused fault
4069 00A5 Memory test detected invalid system
configuration
Action/
Possible Failing FRU
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
CEC backplane
Location: U1.1-P1
Location: U1.1-P1-C1
All memory
Locations:
U1.1-P1-C1
U1.1-P1-M1
U1.1-P1-M2.
Go to "MAP 1540: Minimum
Configuration" on page 113 and run
CEC drawer minimum configuration
to isolate the failing memory
component.
Update system firmware
1. Check for AIX updates
2. Check for system firmware
update
Check for system firmware update
All pluggable memory.
Go to "MAP 1540: Minimum
Configuration" on page 113 and run
CEC drawer minimum configuration
to isolate the failing memory
component.
Application software
Verify system components are
supported and properly installed