Table 6. Service Processor Error Codes. (continued)
Error Code Description
450D 285D Memory system and attention handler
detected fan controller card fault
450D 288D Memory system and attention handler
detected memory riser fault
450D 2A00 Memory system and attention handler
detected 6W processor fault
450D 300A Memory system and attention handler
detected 32MB DIMM fault
450D 300B Memory system and attention handler
detected 128MB DIMM fault
450D 300C Memory system and attention handler
detected 256MB DIMM fault
450D 300D Memory system and attention handler
detected 512MB (stacked) DIMM
fault
450D 300E Memory system and attention handler
detected 512MB (unstacked) DIMM
fault
450D 301F Memory system and attention handler
detected 128MB DIMM fault
Action/
Possible Failing FRU
Fan controller card
Locations:
U0.1-X2
U1.1-X2
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
Processor card
Location: U1.1-P1-C1
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Chapter 5. Error Code to FRU Index