Table 6. Service Processor Error Codes. (continued)
Error Code Description
4067 0122 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0123 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0124 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 012D 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0131 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0132 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0133 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0134 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 013D 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 01FF 6xx bus processor runtime
diagnostics detected memory on riser
card fault
4067 0200 6xx bus processor runtime
diagnostics detected memory riser
card fault
4067 0201 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0202 6xx bus processor runtime
diagnostics detected memory DIMM
fault
4067 0203 6xx bus processor runtime
diagnostics detected memory DIMM
fault
Action/
Possible Failing FRU
Memory DIMM
Location: U1.1-P1-M2.5
Memory DIMM
Location: U1.1-P1-M2.12
Memory DIMM
Location: U1.1-P1-M2.6
Memory DIMM
Location: U1.1-P1-M2.5 x4
Memory DIMM
Location: U1.1-P1-M2.9
Memory DIMM
Location: U1.1-P1-M2.7
Memory DIMM
Location: U1.1-P1-M2.10
Memory DIMM
Location: U1.1-P1-M2.8
Memory DIMM
Location: U1.1-P1-M2.7 x4
Memory failure on riser card 2 that
cannot be automatically isolated. Go
to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
Memory riser card
Location: U1.1-P1-M1
Memory DIMM
Location: U1.1-P1-M1.15
Memory DIMM
Location: U1.1-P1-M1.1
Memory DIMM
Location: U1.1-P1-M1.16
Chapter 5. Error Code to FRU Index