Hide thumbs Also See for 8408-E8D:
Table of Contents

Advertisement

Quick Links

Power Systems
Installing the IBM Power 750
(8408-E8D)
and IBM PowerLinux 7R4 (8248-L4T)
GI11-9890-01

Advertisement

Table of Contents
loading

Summary of Contents for IBM 8408-E8D

  • Page 1 Power Systems Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) GI11-9890-01...
  • Page 3 Power Systems Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) GI11-9890-01...
  • Page 4 Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 43, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. This edition applies to IBM Power Systems servers that contain the POWER7 processor and to all associated models.
  • Page 5: Table Of Contents

    Safety notices ....... . . v Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) ..1 What's new in Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) .
  • Page 6 Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 7: Safety Notices

    You should also refer to the safety information documentation any time you do not clearly understand any safety information in the U.S. English publications. Replacement or additional copies of safety information documentation can be obtained by calling the IBM Hotline at 1-800-300-8751.
  • Page 8 Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v Connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 9 Observe the following precautions when working on or around your IT rack system: v Heavy equipment–personal injury or equipment damage might result if mishandled. v Always lower the leveling pads on the rack cabinet. v Always install stabilizer brackets on the rack cabinet. v To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet.
  • Page 10 Pack the rack cabinet in the original packaging material, or equivalent. Also lower the leveling pads to raise the casters off of the pallet and bolt the rack cabinet to the pallet. (R002) (L001) (L002) viii Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 11 (L003) All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class 1 laser products. Outside the U.S., they are certified to be in compliance with IEC 60825 as a class 1 laser product.
  • Page 12 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call. (C003)
  • Page 13: Installing The Ibm Power 750 (8408-E8D) And Ibm Powerlinux 7R4 (8248-L4T)

    What's new in Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) Read about new or significantly changed information in Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) since the previous update of this topic collection.
  • Page 14: Before You Begin

    1. “Installing the server into a rack” on page 3. 2. “Cabling the server and setting up the console” on page 19. 3. “Completing the server setup” on page 27. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 15: Installing The Server Into A Rack

    4. At the rack front, align the bottom of the right rail with the bottom hole (c) of the EIA unit selected, in both the front of the rack and the rear of the rack. The locator pins (B) fit into holes (b) and (c) of © Copyright IBM Corp. 2013...
  • Page 16 7. Secure both rails to the front EIA support flange using two M5 x 16mm screws (C). 8. At the rear of the rack, rotate the hinged rail latch upward to hold each rail in place against the rear EIA support flange. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 17: Removing The Power Supply Shipping Bracket And The Shipping Covers

    Figure 3. Rear of rack rail alignment and nut clip locations 9. Secure both rails to the rear EIA support flanges using four M5 x 16mm screws (C). Removing the power supply shipping bracket and the shipping covers If you haven't already done so, remove the front and rear shipping covers and the rear shipping bracket before you remove the processor assembly and install the system chassis.
  • Page 18: Removing The System Processor Assembly

    Hold and pull both the handles and begin sliding the system processor assembly out of the enclosure until the slide release buttons on each side of the processor assembly lock into place. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 19 Figure 5. Preparing to remove the system processor assembly 2. Remove the system processor assembly. a. Slide the card release tabs (C) toward the rear of the system. 3. With two people, one on each side of the assembly, lift the system processor assembly off of the rails by using both handles on each side.
  • Page 20: Installing The Chassis Lift Handles

    Figure 7. Push in the system processor assembly rails Installing the chassis lift handles Install the removable system lift handles onto each side of the system chassis. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 21: Installing The Ibm Power 750 (8408-E8D) And Ibm Powerlinux 7R4 (8248-L4T) System Into The Rack

    Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) system into the rack Use the procedure in this section to install the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) systems into the rack. The information provided is intended to promote safety and reliable operation.
  • Page 22 Lift the system. b. Tilt the system into position over the rack rails. c. Carefully lower the system until the rear of the system rests on the rails. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 23 Figure 10. Positioning the system so that it rests on the rack rails 3. While the rear of the system is resting on the rails, have the two people on either side of the system support the weight of the system from the bottom of the chassis. 4.
  • Page 24 5. Push the system all the way into the rack. 6. Install the screws (A) to secure the system to the rack. Figure 12. Pushing the system into the rack Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 25 7. Move to the rear of the system, and,attach the left and right tie-down brackets (A) with four M5 x 16mm screws (two on each bracket), as shown in the following figure. The tie-down brackets ensure that the chassis is securely fastened to the rack. Figure 13.
  • Page 26: Replacing The System Processor Assembly

    With the system processor assembly secured on the rails, lift the slide release buttons (one on each side) to unlock the rails (B). e. By using the lower handles, slide the system processor assembly completely into the enclosure. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 27 Figure 16. Installing the system processor assembly 3. Complete installing system processor assembly: a. Ensure that the handles (C) are in the unlocked position. b. Rotate the handles (C) up and push them toward the enclosure until they lock into place. c.
  • Page 28: Installing The Cable-Management Bracket

    1. For information about connecting expansion units, see Enclosures and expansion units (http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/p7ham/expansionunit.htm). 2. For information about connecting the disk drive unit, see Disk drives (http:// publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/p7hal/p7halkickoff.htm). Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 29: Model Ibm Power 750 (8408-E8D) And Ibm Powerlinux 7R4 (8248-L4T) Pci Adapters

    Model IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) PCI adapters You can remove, replace, or install PCI adapters in the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T) systems. If you are installing a new adapter, see PCI adapter placement (http://publib.boulder.ibm.com/ infocenter/systems/scope/hw/topic/p7hak/p7hak_pciadapters_front_75x_76x.htm) for slot placement...
  • Page 30 Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 31: Cabling The Server And Setting Up The Console

    , Linux, or VIOS Yes for VIOS, no for Serial cable equipped “Cabling the server AIX and Linux with a null modem with an ASCII terminal” Hardware AIX, IBM i, Linux, or Ethernet (or crossover “Cabling the server to Management Console VIOS cable) the Hardware Management Console”...
  • Page 32 You have completed the setup for an ASCII terminal, and have started the ASMI. 8. Continue with “Completing the server without using a management console” on page 29. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 33: Cabling The Server To The Hardware Management Console

    Using service applications, the HMC communicates with managed systems to detect, consolidate, and forward information to IBM service for analysis. If you have not already done so, install and configure your HMC. For instructions about installing and configuring the HMC, see Installation and configuration scenarios (http://publib.boulder.ibm.com/...
  • Page 34: Cabling The Server And Accessing The Integrated Virtualization Manager

    3) Select Boot to SMS menu in the AIX or Linux partition mode by boot field. ® 4) If you are installing the Integrated Virtualization Manager on an IBM System i model, select AIX or Linux in the Default partition environment field.
  • Page 35: Cabling The Server And Accessing Operations Console

    Sign on to the PC by using the local administrator account. b. Ensure that you have installed a full version of IBM i Access with the latest service pack. The Web site to download the latest service pack for IBM i Access can be found at IBM i Access (http://www-03.ibm.com/systems/i/software/access/windows/casp.html).
  • Page 36 For IBM i V5R4 and earlier only: The service tool console IP address can be specified as the name. 2) If you are using IBM i V5R4, set the target partition to 1. If you are using IBM i V6R1 and later, press the Tab key. The Service TCP/IP Address field is enabled.
  • Page 37: Connecting The Monitor, Keyboard, And Mouse To The System

    A6005008, leave the server in this state and call your IBM service provider for assistance. Note: You should configure and start an IBM i TCP interface on a second port (T2, T3, T4) prior to moving the console. This action ensures there is an alternate method to access the server.
  • Page 38 If none of the indicators are flashing, check the power cord connections. For detailed information, see “Common system attention LEDs and system reference codes” on page 40. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 39: Completing The Server Setup

    LEDs and system reference codes” on page 40. 3. Change the managed system passwords by completing the following steps: a. In the navigation area, expand Systems Management > Servers. b. In the content area, select the managed system. © Copyright IBM Corp. 2013...
  • Page 40 For instructions about creating partitions, see Partitioning with the HMC (http:// publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/p7hat/iphbllparwithhmcp6.htm). v For instructions about deploying system plans, see Deploying a system plan by using an HMC (http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/p7hc6/ iphc6deploysysplanp6.htm). Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 41: Completing The Server Without Using A Management Console

    For instructions to install the AIX operating system, see Installing AIX (http:// publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/ipha8/iphayinstallaix.htm). v For instructions to install IBM i, seeInstalling IBM i (http://publib.boulder.ibm.com/infocenter/ systems/scope/hw/topic/ipha8/iphaxinstallos400.htm). v For instructions to install the Linux operating system, see Installing Linux on Power Systems servers (http://publib.boulder.ibm.com/infocenter/lnxinfo/v3r0m0/topic/liaae/...
  • Page 42 Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 43: Reference Information

    Where to find associated information Check the prerequisites. For more information, see “Prerequisite for installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)” on page 1. Perform the inventory. For more information, see “Before you begin” on page 2.
  • Page 44: Installing The Factory-Racked Server

    Table 4. Tasks to install factory-racked server Task Where to find associated information Check the For more information, see “Prerequisite for installing the IBM Power 750 (8408-E8D) and IBM prerequisites. PowerLinux 7R4 (8248-L4T)” on page 1. Perform the For more information, see “Before you begin” on page 2.
  • Page 45 Table 4. Tasks to install factory-racked server (continued) Task Where to find associated information Remove the orange shipping covers on the front of the system. Figure 19. Remove the shipping cover on the front of the system Remove the shipping brackets on the rear of the system.
  • Page 46 Figure 21. Remove the shipping bracket Remove the shipping brackets on the rear of the system. Figure 22. Remove the shipping bracket Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 47 Table 4. Tasks to install factory-racked server (continued) Task Where to find associated information Remove the shipping brackets on the rear of the system. Figure 23. Remove the shipping bracket Note: Ensure that you fully seat the server power supplies after removing the rear shipping bracket.
  • Page 48: Supporting Information For Setting Up Consoles

    To set up the Web browser for direct or remote access to the ASMI, complete the following steps: 1. If the server is not powered on, perform the following steps: a. Connect your power cord or cords to the server. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 49 b. Plug the power cord or cords into the power source. c. Wait for the control panel to display 01. A series of progress codes are shown before 01 appears. Notes: v The system is powered on if the light on the control panel is green. v To view the control panel, press the blue switch to the left, then pull out the control panel all the way, and then pull it down.
  • Page 50: Setting The Ip Address On Your Pc Or Notebook

    8. Click OK on the Local Area Connection Properties window. It is not necessary to restart your PC. Windows Vista To set the IP address within Windows Vista, complete the following steps: 1. Click Start > Control Panel. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 51: Windows 7

    Determine the current IP address. For more information about determining the current service processor IP address, see Function 30: Service processor IP address and port location (http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/p7hb5/func30.htm). v Move the reset toggle switches on the service processor from their current position to the opposite position.
  • Page 52: Common System Attention Leds And System Reference Codes

    Your power voltages do not Ensure that you are using the correct power voltage. match Refer to your server's specifications to learn more about the power voltage that your server requires. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 53: Best Practices For Integrating Cable And System Placement

    Table 7. Common installation SRCs (continued) Error description Recovery steps Starts with 27xxx, Fibre Channel port failure These errors are often caused by ports that are not used. 28xx, 57xxx Every port must have a cable or wrap plug installed. Whenever a cable is not installed, ensure that a wrap and ends with plug is installed for each unused port.
  • Page 54 (PDU) so that the wall-to-PDU line cord can be attached to the PDU. v Use hook-and-loop fasteners where necessary. Figure 24. Cable management bridge lances Figure 25. Cable bend radius Related information: POWER7 770/780 Cabling guide Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 55: Notices

    All statements regarding the manufacturer's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only. The manufacturer's prices shown are the manufacturer's suggested retail prices, are current and are subject to change without notice. Dealer prices may vary. © Copyright IBM Corp. 2013...
  • Page 56: Trademarks

    IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
  • Page 57 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 58 Declaration: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may need to perform practical action. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 59 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 60: Class B Notices

    This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 61 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment.
  • Page 62 IBM Taiwan Contact Information Electromagnetic Interference (EMI) Statement - Korea Germany Compliance Statement Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse B EU-Richtlinie zur Elektromagnetischen Verträglichkeit Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
  • Page 63: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 64 IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed. You may not download, export or re-export this information except in full compliance with all applicable laws and regulations, including all United States export laws and regulations.
  • Page 66 Part Number: 00L5075 Printed in USA GI11-9890-01...