IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 354

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
336
Service Guide
Error Code Description
4B29 288D Processor system and memory test
detected memory riser fault
4B29 2A00 Processor system and memory test
detected 6W processor fault
4B29 300A Processor system and memory test
detected 32MB DIMM fault
4B29 300B Processor system and memory test
detected 128MB DIMM fault
4B29 300C Processor system and memory test
detected 256MB DIMM fault
4B29 300D Processor system and memory test
detected 512MB (stacked) DIMM
fault
4B29 300E Processor system and memory test
detected 512MB (unstacked) DIMM
fault
4B29 301F Processor system and memory test
detected 128MB DIMM fault
Action/
Possible Failing FRU
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
Processor card
Location: U1.1-P1-C1
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn

Advertisement

Table of Contents
loading

Table of Contents