Table 2. Firmware Checkpoints (continued)
Checkpoint
E5xy (E511 - E5FF)
Where x is not equal
to 0, and y is not
equal to 0.
E600
E601
E602
E603
156
Service Guide
Description
Configure remote I/O subsystem
components
SSA PCI adapter open firmware
has run successfully.
SSA PCI adapter BIST has started
but failed to complete after four
seconds.
SSA PCI adapter open firmware
has started.
SSA PCI adapter BIST has
completed with an error.
Action/
Possible Failing FRU
The E5xy (E511 to E5FF) codes
are reserved for activities relating
to configuration or testing of the I/O
subsystem, or remote I/O
subsystem. A hang at one of these
codes implies that a severe error
occurred during the programming
of I/O subsystem registers or when
interacting with adapters plugged
into the system. The last two digits
in the checkpoint can be used to
help isolate the location of the I/O
activity that caused the problem.
"x" indicates the I/O drawer
number. "y" indicates the PCI bus
occurrence.
If y=_, then the PCI Bus is:
Y = PCI Bus
1 = 0
2 = 1
3 = 2
4 = 3
See "AIX and Physical Location
Code Tables" in Chapter 1, for
location codes.
Using the information above, go to
"MAP 1540: Minimum
Configuration" on page 113.
Replace the adapter. See
"Checkpoint and Error Code Index"
on page 165 for location code
information related to this error.
Replace the adapter. See
"Checkpoint and Error Code Index"
on page 165 for location code
information related to this error.
Replace the adapter. See
"Checkpoint and Error Code Index"
on page 165 for location code
information related to this error.
Replace the adapter. See
"Checkpoint and Error Code Index"
on page 165 for location code
information related to this error.