Avaya PARTNER Advanced Communications System Installation And Use Manual page 228

Advanced communications system
Hide thumbs Also See for PARTNER Advanced Communications System:
Table of Contents

Advertisement

®
PARTNER
Advanced Communications System Installation, Programming, and Use
Dialing restrictions for extensions not in the Night Service Group remain the same as during
normal daytime operation.
If you reassign the Night Service Button, it is removed from the button where it was
previously assigned.
If you program a System Password (#403), you must enter the password when turning Night
Service on or off. In addition, when Night Service is on, users in the Night Service Group
can dial only numbers on the Emergency Phone Number List (#406) and Marked System
Speed Dial numbers without entering the System Password. Night Service with a System
Password is useful for controlling unauthorized use of phones after hours.
If you have a voice messaging system, VMS Hunt Schedule (#507) determines when outside
calls should ring the VMS Hunt Group (always, day only, or night only). The status of the
Night Service Button at extension 10 tells the voice messaging system to operate in day or
night mode.
The Night Service Button returns to the status (on/off) it was in immediately prior to a power
failure or to System Reset (#728) being used.
Night Service is unavailable on T1 lines with Direct Inward Dialing (DID).
Programming
To program a Night Service Button at extension 10:
f00ss#503
1. Press
2. Do one of the following:
If you want to assign Night Service to the first available button, press
display similar to the following appears:
Night Service Button
1 Assigned - Ext10
If you want to remove the Night Service Button assignment, press
display similar to the following appears:
Night Service Button
2 Not Assigned (the factory setting) 
If you want to assign Night Service to a specific button, press
following appears:
Night Service Button
3 Select a Button
Then press a programmable button with lights to assign Night Service to that button.
3. Select another procedure, or exit programming mode.
4. Label the Night Service Button at extension 10.
Using the Night Service Button
To turn Night Service on:
Night Service Button (#503)
7-16
7
at extension 10.
D
D
3
. A display similar to the
7
until a
until a

Advertisement

Table of Contents
loading

This manual is also suitable for:

Partner acs