Connecting The Local Terminal/Setting The Baud Rate; Connections Between An External Modem And The Octel 200/300 - Avaya Octel 200 Installation And Maintenance Manual

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

4−16
Installation and Maintenance Volume

Connecting the Local Terminal/Setting the Baud Rate

The following explains how to connect a local terminal and set the baud rate. The Octel 200/300 default
baud rate for the direct terminal connection is 9600. You can adjust the baud rate by using the BAUD
command.
1. Connect the terminal to the RS-232C connector marked J1 in the rear of the cabinet or to SP1 in the
front.
2. Turn the terminal ON and set the terminal baud rate.
Set the terminal baud rate to any of the valid rates: 300, 600, 1200, 2400, 4800, 9600, 19200 or
38400.
3. Turn the message server power ON.
Immediately following power up, press
establish the baud rate at this time the header and diagnostic messages print at 9600 baud.
Upon power up, the message server executes a power-on selftest diagnostic, or Boot ROM
diagnostic. Wait for the operating system to load and the diagnostic selftest to finish. If the tests were
completed successfully, the Octel 200/300 displays INITIALIZING PORTS...PORT
INITIALIZATION DONE. Refer to the Octel 200/300 Hardware Installation section in this chapter
for an illustration of the boot up screen.
4. When you see the Port Initialization Done prompt, press
5. When the password prompt displays, enter the password and press
.
6. The operating system @ prompt appears.

Connections Between an External Modem and the Octel 200/300

You can use an external modem, which appears to the message server as a directly connected terminal.
The external modem can operate at speeds up to 38,400.
Table 4-5 lists the pinouts for an external modem connection. Figure 4-7 is a diagram of external modem
pinouts.
Modem
Pin
Number
2
3
5
4
7
8
20
Octel 200/300
S.4.1
Default passwords for new servers are created by the manufacturer. For the report,
administrative, and maintenance levels, the default passwords are REPORT, ADMIN, and
MAINT, respectively. For security, create new server passwords as soon as possible. Refer to
the Maintenance chapter, Miscellaneous Commands section, for information about setting
passwords.
Table 4-5 Pinouts for External Modem Connections
Octel 200/300
Pin Number
3
2
4
5
7
20
8
repeatedly to establish the baud rate. If you do not
Enter
Enter
Modem Signal
Name/Function
Transmit data
Receive data
CTS
RTS
Signal ground
DCD
DTR
to display the password prompt.
.
Enter
Octel 200/300
Name/Function
Receive data
Transmit data
RTS
CTS
Signal ground
DTR
DCD
PB60019−01