Power Supply Unit (Psu) - Avaya Octel 200 Installation And Maintenance Manual

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

Power Supply Unit (PSU)

There are eight different Power Supply Units (PSUs) for the Octel 200/300. The differences between
the PSUs are explained in this section.
.
The information in this section applies to all PSUs unless otherwise noted.
Caution!
Octel 200 180–260 VAC
Octel 300 180–260 VAC
Octel 200 −48 VDC (unchanged)
Octel 300 −48 VDC (unchanged)
PSU Identification
You can identify which PSU is in your Octel 200/300 by the label as listed below:
The front label:
The bar code label:
Octel 200 only:
P.S. Warning/Fuse Label:
Size: 5x20mm
Rating: 6.3 Amp, 250V, Slow Blow
*The actual part number is on the back of the PSU. Refer to Table 2-3 for the actual part numbers.
PB60019−01
A PSU with the correct input voltage must be
used.
Do not install or remove the PSU with the
power switch in the ON position.
Earlier Version PSUs
Octel 200 90–132 VAC
(110/220 VAC nominal)
(220/230 VAC nominal)
Octel 300 90–132 VAC
(220/230 VAC nominal)
(220/240 VAC nominal)
Current AC PSU
100−240 VAC PSU
Part Number*
Current Version PSUs
Octel 200 100−240 VAC
autoranging
Octel 300 100−240 VAC
autoranging
Octel 200 −48 VDC (unchanged)
Octel 300 −48 VDC (unchanged)
Earlier AC PSU
Front Label Octel 200 120VAC: AC PSU
Front Label Octel 300120VACl: AC PSU
Front Label Octel 200 230VAC: 230 VAC PSU
Front Label Octel 300 240VACl: 240 VAC PSU
Octel 200 only:
P.S. Warning/Fuse Label:
(Three check boxes for three possible fuses 10 A,
5 A, or 15 A).
Replacement fuse: 250V, Fast Blow.
Hardware
2-11
Octel 200/300
S.4.1

Advertisement

Table of Contents
loading