Avaya Octel 200 Installation And Maintenance Manual page 297

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

66
67
68
69
70
71
72
PB60019−01
DOUBLE INTERRUPTED RINGBACK MINIMUM TONE OFF LONG PERIOD
The shortest delay that a TONE OFF, of the long TONE OFF period, can be to qualify as a
double interrupted ringback.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a double interrupted ringback. If the TONE OFF is shorter than this delay, the
message server assumes that it is not a double interrupted ringback.
DOUBLE INTERRUPTED RINGBACK MAXIMUM TONE OFF SHORT PERIOD
The longest delay that a TONE OFF, of the short TONE OFF period, can be to qualify as a
double interrupted ringback.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a double interrupted ringback. If the TONE OFF is longer than this delay, the
message server assumes that it is not a double interrupted ringback.
DOUBLE INTERRUPTED RINGBACK MINIMUM TONE OFF SHORT PERIOD
The shortest delay that a TONE OFF, of the short TONE OFF period, can be to qualify as a
double interrupted ringback.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is double interrupted ringback. If the TONE OFF is shorter than this delay, the
message server assumes that it is not a double interrupted ringback.
SLOW BUSY MAXIMUM TONE ON PERIOD
The longest delay that a TONE ON can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONE ON is longer than this delay, the message server
assumes that it is not a slow-busy tone.
SLOW BUSY MINIMUM TONE ON PERIOD
The shortest delay that a TONE ON can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONE ON is shorter than this delay, the message server
assumes that it is not a slow-busy tone.
SLOW BUSY MAXIMUM TONE OFF PERIOD
The longest delay that a TONE OFF can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONE OFF is longer than this delay, the message server
assumes that it is not a slow-busy tone.
SLOW BUSY MINIMUM TONE OFF PERIOD
The shortest delay that a TONE OFF can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONE OFF is shorter than this delay, the message
server assumes that it is not a slow-busy tone.
Maintenance Commands
6-55
Octel 200/300
S.4.1

Advertisement

Table of Contents
loading

Table of Contents