6-56
Installation and Maintenance Volume
73
74
75
76
Coordinate the following application-delay indexes for cadence recognition. Refer to Table 6-3.
Set index 49 to a value equal to the largest value for any of the following delay indexes: 53, 61, 63,
-
69, or 71.
Set index 50 to a value less than the value for any of the following delay indexes: 54, 62, 64, 70, or 74.
-
Set index 51 to a value equal to the largest value for any of the following delay indexes: 55, 65, 67,
-
71, or 75.
Set index 52 to a value less than the value for any of the following delay indexes: 56, 66, 68, 72, or 76.
-
Table 6-3 Application Delays for Cadence Recognition, for Determining Tone On/Tone Off
Single Interrupt Ringback
Max/Min Acceptable Tone Ranges
Double Interrupt Ringback, long periods
Double Interrupt Ringback, short periods
Slow Busy
Fast Busy
Octel 200/300
S.4.1
FAST BUSY MAXIMUM TONE ON PERIOD
The longest delay that a TONE ON can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE ON is longer than this delay, the message server
assumes that it is not a fast-busy tone.
FAST BUSY MINIMUM TONE ON PERIOD
The shortest delay that a TONE ON can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE ON is shorter than this delay, the message server
assumes that it is not a fast-busy tone.
FAST BUSY MAXIMUM TONE OFF PERIOD
The longest delay that a TONE OFF can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE OFF is longer than this delay, the message server
assumes that it is not a fast-busy tone.
FAST BUSY MINIMUM TONE OFF PERIOD
The shortest delay that a TONE OFF can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE OFF is shorter than this delay, the message server
assumes that it is not a fast-busy tone.
TONE EVENT
Maximum
Minimum
Tone On
Tone On
Index 53
Index 54
Index 49
Index 50
Index 61
Index 62
Index 63
Index 64
Index 69
Index 70
Index 73
Index 74
Maximum
Minimum
Tone Off
Tone Off
Index 55
Index 56
Index 51
Index 52
Index 65
Index 66
Index 67
Index 68
Index 71
Index 72
Index 75
Index 76
PB60019−01