Avaya Octel 200 Installation And Maintenance Manual page 404

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

8-18
Installation and Maintenance Volume
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Error Codes for all DATA values:
00 =
01 =
02 =
04 =
08 =
10 =
20 =
40 =
80 =
FF =
34 Power-ON
Diagnostic Error
DATA-1:
Bit 5:
TIMER
Bit 4:
NMI
Bit 3:
Incorrect checksum fond in code during normal operation
Bit 2:
Normal (error found during normal code operation)
Bit 1:
BOOT (error found during boot process)
Bit 0:
Incorrect checksum found in code during boot process
DATA-2
Bit 7:
Error detected on Link 4
Bit 6:
Error detected on Link 3
Bit 5:
Error detected on Link 2
Bit 4:
Error detected on Link 1
Bit 3:
RAM error type 4
Bit 2:
RAM error type 3
Bit 1:
RAM error type 2
Bit 0:
RAM error type 1
DATA-3 =
UNDEFINED
DATA-4 =
UNDEFINED
Octel 200/300
S.4.1
Source
NO ERRORS DETECTED
CHANNEL STATUS REGISTER ERROR
CVSD DATA REGISTER BIT/ADDRESS ERROR
A/D CONVERTER OR POWER DETECT ERROR
CVSD ENCODING CIRCUIT ERROR
DTMF SENDER, POWER LIMITER ERROR
CVSD DECODING CIRCUIT OR OUTPUT GAIN CIRCUIT ERROR
CVSD DECODING, ENCODING ERROR
DTMF SENDER, DTMF DECODER ERROR, OR BAND PASS FILTER
CIRCUIT ERROR
FATAL ERROR
Selftest for integration
Replace integration card as indicated by
cards.
slot number.
TE INT
LI INT
DATA-1 through
DATA-4 designate
errors found.
Remedy
Priority
2
PB60019−01

Advertisement

Table of Contents
loading