Quick Reference Guide
Taking LAN card out of service and returning it to service
Courtesy Down
Courtesy Up
Digital Network Test
TEST LAN
SNMP Test
TEST SNMP
Maintenance and Troubleshooting
Diagnostic Tools
LAN CARD PING
Echo Test
LAN STATUS
PB60019−01
Command
CD x
CU x
TEST LAN
TEST LAN x
TEST SNMP
CMD x PING y
LANSTAT
Description
Takes the LAN card out of service without interrupting
activities in progress.
x = slot number of LAN card.
Brings the LAN card back into service.
x = slot number of LAN card.
Tests all locations in the digital network.
Tests a single location in the digital network;
x = the specific location name to be tested.
Tests the mechanism of communication between the
Octel 200/300 message servers and the SNMP manager
system.
Lowest level "echo" test from the local LAN to the
destination message server to verify that both LAN cards
are UP, data transfer is possible, and IP addresses are
correct.
x = slot number of LAN card in servers with CPU/VCU
y = IP address of the device to which the Ethernet
packet is sent.
Lists basic information about the current status of the LAN
— UP, DOWN, INITIALIZING.