Avaya Octel 200 Installation And Maintenance Manual page 403

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
01 =
02 =
03 =
04 =
05 =
34. Power-ON
Diagnostic Error
For LIC4
DATA-1 =
PORT 1
DATA-2 =
PORT 2
DATA-3 =
PORT 3
DATA-4 =
PORT 4
PB60019−01
Source
DATA-2 =
REPORTED STATUS
00 =
LSP SUCCESSFULLY STARTED
01 =
SCSI ERROR WHILE LOADING LSP
DATA-4 = ERROR CODE
02 =
CARD TYPE IN SLOT DOES NOT MATCH
CONFIGURED TYPE
DATA-4 =
03 =
CONTROL BUS ERROR − SLOT EMPTY OR
CARD NON-RESPONSIVE
04 =
FILE SYSTEM READ ERROR ACCESSING LSP
IMAGE
05 =
CARD IN SLOT REPORTS FATAL DIAGNOSTIC
ERROR
DATA-3 =
06 =
BAD START LSP REQUEST
89 =
LIC REPORTED LIC IMAGE CHECKSUM
ERROR
DATA-3 =
CURRENT SLOT STATE
00 =
EMPTY (UNCONFIGURED)
01 =
WAITING FOR INITIAL START LSP REPLY
02 =
RUNNING
03 =
ERROR
NO PORTS CONFIGURED FOR LINE CARD
LINE CARD DISALLOWED BY OCC
TOTAL PORTS > ALLOWED BY OCC
ERROR WRITING START LSP REQUEST
DISK ERROR WHEN SEARCHING FOR LSP CODES
Selftest for line cards.
Replace LIC as indicated by slot number.
For LIC 8, TLC 8
DATA-1 =
DATA-2 =
DATA-3 =
DATA-4 =
System Errors and Traffic Pegs
Remedy
CARD TYPE ACTUALLY INSTALLED
IN SLOT
SUPPLEMENTAL CARD STATUS
PORT 1, PORT 2
PORT 3, PORT 4
PORT 5, PORT 6
PORT 7, PORT 8
8-17
Priority
2
Octel 200/300
S.4.1

Advertisement

Table of Contents
loading