Avaya Octel 200 Installation And Maintenance Manual page 71

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

Quick Reference Guide
Heat Dissipation
120, 230 and 240 VAC PSU
100−240 VAC Auto-ranging
PSU
Routine Maintenance
Air Filter Cleaning
Fan Inspection
System Protection
Overtemperature Shutdown
Disk Drive Spin Down
Power Supply Shutdown
Power Supply Unit Protection
Circuit Breaker
Overcurrent
120, 230 and 240 VAC PSU
100−240 VAC Auto-ranging
PSU
Overvoltage
120, 230 and 240 VAC PSU
100−240 VAC Auto-ranging
PSU
Overtemperature
PB60019−01
Octel 300 Message Server Specifications
Maximum 1,000 watts (3412 Btu per hour) per cabinet, each cooled with
four internal, 4-inch (10.2-cm) fans
Maximum 600 WATT, (2047 Btu per hour) per cabinet, each cooled with
two internal, 4-inch (10.2 cm) fans
At least yearly
At least yearly
<41F or >131F (<5C or >55C), automatic recovery
158F (70C), circuit breaker trip, manual recovery
System overcurrent trip, manual recovery
All six DC outputs, automatic recovery
All five DC outputs, automatic recovery
All six DC outputs, circuit breaker trip, manual recovery
All five DC outputs, circuit breaker trip, manual recovery
Circuit breaker trip, manual recovery
Octel 200/300
Hardware
Octel 200/300
S.4.1