Avaya Octel 200 Installation And Maintenance Manual page 69

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

Quick Reference Guide
Electrical Requirements
100−240 VAC Auto-ranging
PSU System
Voltage Range
Frequency
Maximum Power
120-Vac System
Voltage Range
Frequency
Maximum Power
230-Vac System
Voltage Range
Frequency
Maximum Power
–48-Vdc System
Voltage Range
Maximum Power
Remote Alarm
Alarm Relay
Closures
Rating
Access
Alarm Callout
Alarm Types
Temperature Alarm
Environmental Requirements
Temperature
Operating (Sea Level)
Nonoperating
Gradient, Operating
Gradient, Nonoperating
PB60019−01
Octel 300 Message Server Specifications
100−240 VAC
50−60 Hz
500 WATT
90–132 Vac
47–63 Hz
1000 watts
180–260 Vac
47–63 Hz
1000 watts
42–60 Vdc
1000 watts
2 (Major, Minor)
0.5 A at 48 Vdc
Rear, DB9 connector
Automatic Callout to configurable service number
Major Alarm
Minor Alarm
At Alarm Temperatures <50F or >122F (<10C or >50C)
50F (10C) to 104F (40C)
–50F (–10C) to 129F (54C)
18F (10C) per hour, maximum
36F (20C) per hour, maximum
Octel 200/300
Hardware
Octel 200/300
S.4.1

Advertisement

Table of Contents
loading