Avaya Octel 200 Installation And Maintenance Manual page 418

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

8-32
Installation and Maintenance Volume
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
64. LAN Hardware
Error (continued)
03 = REACHED THE MAX. RETRY COUNT WHILE SYNCHRONIZING.
04 = LAN CONTROL BLOCK REQUEST SIZE MISMATCH
05 = LAN CONTROL REPLY BLOCK SIZE MISMATCH
06 = LAN CONTROL BUS TIME OUT DURING READING/WRITING
07 = OEM NCK OF OTHER SYSTEM DOES NOT MATCH OURS
08 = ERROR DURING COURTESY DOWN
Octel 200/300
S.4.1
Source
Problem detected by
Dependent on the DATA-1 values described
the LAN.
below.
FORCED RESET DONE TO SYNCHRONIZE.
The CPU is unable to communicate with the LAN card.
Same as for DATA-1 = 02.
REMEDY:
Compatibility problem with the LAN card.
Contact your technical support center.
REMEDY:
Compatibility problem with the LAN card.
Contact your technical support center.
REMEDY:
CONTROL BUS
Problem with the LAN card.
Contact your technical support center.
REMEDY:
OEM type between systems is incompatible.
Use the LANSTAT command to determine which location
REMEDY:
is in the OEM-FAIL state. Check the OEM type of the
current system. Contact your technical support center.
An error occurred while executing the courtesy down command.
DATA-2 =
ERROR CODES:
01 =
COURTESY DOWN STATE
02 =
COURTESY STATE STATE
DATA-3 =
ERROR CODES
01 =
LAN EVENT TIMEOUT
02 =
VCU EVENT TIMEOUT
03 =
INVALID LAN SLOT
Try the courtesy down command again. If the problem
REMEDY:
continues, contact your technical support center.
Remedy
Priority
3
1
PB60019−01