Chapter 5 Administration
Configuring the Autoloader

Setting the SCSI ID

5

Setting Ethernet

5
62
To configure the Quantum SuperLoader 3 autoloader, you must verify
the setup of the following:
SCSI ID(s). For the autoloader, there is a single SCSI ID.
Magazine(s).
Ethernet IP address (if you are not using DHCP).
SNMP server IP address only if SNMP is being used.
Time server IP address (or the time zone, date, and time, if
configuring manually)—only if a time server is being used.
Control mode.
Security option.
Each SCSI device attached to a server or workstation must have a unique
SCSI ID. For the SuperLoader 3 autoloader, you need one SCSI ID.
To set the SCSI ID:
1 If the main menu is not already visible, press
2 On the main menu, scroll to
3 On the
Configuration
4 Scroll to the number you want to set as the autoloader's SCSI ID, then
press
.
Enter
Cycle Power new SCSI ID
5 Press and hold the power button on the front panel until
Shutdown wait 60 sec
LCD, then the autoloader shuts off.
6 Press the power button again to power on the autoloader. The new
SCSI ID is now in effect.
Ethernet is the method used by the autoloader to access a network. With
an Ethernet connection, you can remotely access the autoloader over the
network. To use the Ethernet connection, you must define the following:
A dynamic or static IP address for the autoloader (required)
A subnet mask (required)
An IP gateway (optional)
SuperLoader 3 Autoloader User's Guide
Configuration
submenu, scroll to
SCSI ID
appears on the LCD.
appears on the LCD.
Power Off
.
Enter
and press
.
Enter
and press
.
Enter