Table 10 Hard Error
Log Field Descriptions
Error Code Field
Description
8
Field
Time Stamp
Error Code
Context
Error codes appear as 8-character strings made up of either letters or
numbers for a total of 32 bits. The following table shows the block
descriptor for the Hard Error log codes.
SuperLoader 3 Autoloader User's Guide
Chapter 8 Troubleshooting
Checking for Errors
Description
The time the event occurred. This
field helps correlate the event
with a possible application
interruption. If the unit is unable
to acquire the correct time/date
from the SNTP time server, or the
front panel, the time stamp
contains values indicating the
power cycle number and the time
an entry was written relative to
that power cycle, listed as Power
On Hours (POH).
The unit has no internal
Note:
real-time clock and
requires the user to set
the time of day from the
front panel or the
network interface
(SNTP).
The type of error and action to
which the event is related. This
field helps identify what caused
the event to occur.
The event's software register
information.