Perform A Post; Interpret The Post Results; Diagnostic Tests From The Front Panel - Freecom SUPERLOADER3 LTO2-HH Manual

Hide thumbs Also See for SUPERLOADER3 LTO2-HH:
Table of Contents

Advertisement

Perform a POST

6
Interpret the POST
Results
6

Diagnostic Tests from the Front Panel

If you experience errors while operating your autoloader, you may need
to reboot the autoloader to perform a POST.
To reboot the SuperLoader 3 Autoloader:
1 Hold down the power button until
appears.
2 Release the power button. The autoloader turns off.
3 Press the power button again to turn the autoloader on. POST runs
automatically.
While the POST is running, a progress indicator showing the name of the
test displays on the front panel. If the autoloader is working properly, the
message
System Ready
POST completes successfully.
If the autoloader is not working properly, error messages display on the
front panel (see
Checking for Errors
Diagnostic tests allow you to calibrate parts of the autoloader, check the
condition of parts, or test the autoloader's functionality. From the front
panel, you can perform all of the diagnostic tests. Because certain tests
require you to manually insert a cartridge, you can perform only some of
the diagnostic tests using On-board Remote Management (see
Remote Management Diagnostic Tests
Note:
On-board Remote Management allows you to request all
diagnostic tests, but any tests that require a cartridge to be
inserted will time-out unless someone manually inserts the
cartridge at the appropriate time.
SuperLoader 3 Autoloader User's Guide
Diagnostic Tests from the Front Panel
System Shutdown Please Wait...
and the current configuration display after the
on page 114).
on page 78
Chapter 6 Diagnostics
On-board
).
6
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quantum superloader 3

Table of Contents