Appendix B
Catalyst 3750-X and 3560-X Switch Debug Commands
Defaults
Authentication debugging is disabled.
Command Modes
Privileged EXEC
Command History
Release
12.2(53)SE2
Usage Guidelines
The undebug authentication command is the same as the no debug authentication command.
On a 3750-E switch, when you enable debugging, it is enabled only on the stack master.
To enable debugging on a stack member, you can start a session from the stack master by using the
session switch-number privileged EXEC command and then entering the debug authentication
command at the command-line prompt of the stack member. You also can use the remote command
stack-member-number line privileged EXEC command on the stack master switch to enable debugging
on a stack member.
Related Commands
Command
authentication
control-direction
authentication
event
authentication
fallback
authentication
host-mode
authentication open
authentication
order
authentication
periodic
authentication
port-control
authentication
priority
authentication
violation
show
authentication
OL-21522-02
Modification
This command was introduced.
Description
Configures the port mode as unidirectional or bidirectional.
Sets the action for specific authentication events.
Configures a port to use web authentication as a fallback method for clients that
do not support IEEE 802.1x authentication.
Sets the authorization manager mode on a port.
Enables or disables open access on a port.
Sets the order of authentication methods used on a port.
Enables or disables reauthentication on a port.
Enables manual control of the port authorization state.
Adds an authentication method to the port-priority list.
Configures the violation modes that occur when a new device connects to a port
or when a new device connects to a port after the maximum number of devices
are connected to that port.
Displays information about authentication manager events on the switch.