Omron 3G3MV-PDRT2 User Manual page 357

Devicenet communications units
Table of Contents

Advertisement

Appendices
Con-
Regis-
Class 64 (hex)
stant
ter num-
In-
ber
stance
(hex)
F6-01
0395
---
F7-01
0396
---
F8-01
0398
---
F9-01
0399
---
F9-02
039A
---
F9-03
039B
---
F9-04
039C
---
F9-05
039E
---
F9-06
039F
---
Note 1. When the control mode is changed, the Inverter will revert to default settings. (The open loop
vector control default settings are given above.)
Note 2. Within the setting range (1 to 38), 4, 10, 11, 12, 13, 14, 25, 28, 34, and 35 cannot be set,
and 29 to 31 are not used.
External Terminal Function Parameters
Con-
Regis-
Class 64 (hex)
stant
ter num-
In-
ber
stance
(hex)
H1-01
0400
01
H1-02
0401
01
H1-03
0402
01
H1-04
0403
01
H1-05
0404
01
H1-06
0405
01
H2-01
0406
01
H2-02
0407
01
H2-03
0408
01
H3-01
0409
01
H3-02
040A
01
H3-03
040B
01
H3-04
040C
01
H3-05
040D
01
Name
At-
tribute
---
Not used.
---
Output pulse multiple selection
---
Operation selection (E-15)
---
Communications external fault input
selection
---
Communications external fault input
detection selection
---
Communications external fault input
operation selection
---
Not used.
---
Torque reference/Torque limit selection
from communications
---
DeviceNet operation selection
Name
At-
tribute
7E
Multi-function input 1: terminal 3 selec-
tion
7F
Multi-function input 2: terminal 4 selec-
tion
80
Multi-function input 3: terminal 5 selec-
tion
81
Multi-function input 4: terminal 6 selec-
tion
82
Multi-function input 5: terminal 7 selec-
tion
83
Multi-function input 6: terminal 8 selec-
tion
84
Multi-function contact output: terminal
9 to 10.
85
Multi-function output 1: terminal 25.
86
Multi-function output 2: terminal 26.
87
Signal selection: terminal 13 (Voltage)
88
Frequency reference (voltage)
gain: terminal 13
89
Frequency reference (voltage)
bias: terminal 13
8A
Multi-function analog input signal
selection: terminal 16
8B
Multi-function analog input signal
selection: terminal 16
Chapter 10
Setting
Setting
Default
range
unit
setting
---
---
0
0 to 4
1
1
0 to 3
1
1
0, 1
1
0
0, 1
1
0
0 to 3
1
1
---
---
0
0, 1
1
1
0 to 3
1
1
Setting
Setting
Default
range
unit
setting
0 to 77
1
24
14
3 (0)
(See
note 1.)
4 (3)
(See
note 1.)
6 (4)
(See
note 1.)
8 (6)
(See
note 1.)
0 to 37
1
0
1
2
0, 1
1
0
0.0 to
0.1%
100.0
1000.0
−100.0 to
0.1%
0.0
100.0
0, 1
1
0
0 to 1F
1
1F
Write
during
opera-
tion
---
No
No
No
No
No
---
No
No
Write
during
opera-
tion
No
No
No
No
No
No
No
No
No
No
Yes
Yes
No
No
10-99