Remote I/O Functions
5-7

Unit Status

This section explains the Unit status information, which is allocated in the Master when remote I/O
communications are used and can be used to easily monitor the Unit's status. Refer to 5-2 Switching
the Remote I/O Function for details on allocating unit status to the Master. Refer to 7-2 Smart Slave
Functions for details on making settings such as each functions threshold value.
Note When using the control I/O remote I/o function, there is a default setting available (a default
connection path setting), which attaches the unit status (16 bits) to the remote I/O.
5-7-1 Unit Status
This section explains the I/O format (allocated words) and bit/data functions when the unit status is
allocated to a COS connection.
I/O Format (Allocated Words)
Inputs (Inverter to PLC)
Byte number
Wd M
Right-
0
Con-
most
nected
compo-
nent
mainte-
nance
flag
Left-
1
Error flag Inverter detected fault code
most
Note 1. A shaded box indicates that the bit is not used.
Note 2. Outputs (PLC to Inverter) cannot be allocated.
5-30
Bit 7
Bit 6
Bit 5
Opera-
Warning
tion time
torque
over flag
detected
flag
Instance ID: 154 Decimal (9A Hex)
Bit 4
Bit 3
Bit 2
Cooling
Inverter
Network
fan/elec-
unit
power
trolytic
mainte-
voltage
capaci-
nance
drop flag
tor main-
flag
tenance
flag
Chapter 5
Bit 1
Bit 0